Separate plumbing from ACR tube
ASTM B88 water tube uses nominal sizing and defined wall types. ACR tube uses actual OD and a refrigerant-service internal condition.
Manufactured in Gujarat · Water-service tube · Export enquiries
Specify seamless copper water tube by standard, nominal size, wall type, temper and documentation for plumbing and building-services projects.

Copper tube for water and building services
Copper plumbing tube is normally ordered under ASTM B88/B88M or a recognised regional water-tube standard such as EN 1057. ASTM B88 classifies seamless copper water tube as Type K, L, M or DWV. These types share the same outside diameter at a given nominal size but use different wall thicknesses.
Type names are not interchangeable approvals. The permitted application depends on the adopted plumbing or mechanical code, design pressure, temperature, joining method, water chemistry and project specification. State the standard, nominal size, type, grade, temper, length, quantity and documentation in the enquiry.
A clearer route to the correct water tube
ASTM B88 water tube uses nominal sizing and defined wall types. ACR tube uses actual OD and a refrigerant-service internal condition.
A structured wall comparison helps the buyer identify the product type specified by the engineer or governing code.
Material certificates, test scope, marking and third-party inspection can be stated before commercial review.
Use the 3D product builder to organise the tube form and purchasing details before sending the RFQ.
The buyer and system designer remain responsible for confirming code acceptance, water quality and service suitability.
Technical specification
Values are based on the group’s published ASTM B88 range. Final dimensions, tolerance, temper, marking, tests and availability are confirmed against the selected standard and RFQ.
Potable-water approval is project and jurisdiction specific. State whether NSF/ANSI 61, regional approval, dual marking or other compliance evidence is required.
Wall-type selection
The type identifies a wall series within ASTM B88. It does not replace engineering calculations or local-code review.
| Tube type | Relative wall | Common selection context | Important limitation |
|---|---|---|---|
| Type K | Heaviest of K/L/M | Underground water service, fire protection or higher-duty installations where specified | Confirm pressure, temperature, burial and local-code requirements |
| Type L | Medium | Interior plumbing, hydronic and building-services installations where permitted | Do not assume suitability for medical gas or refrigerant service |
| Type M | Lighter | Above-ground water service only where the adopted code permits | Lower wall thickness; not allowed for every application or jurisdiction |
| DWV | Drainage wall series | Drain, waste and vent systems | Not intended as pressure water tube |
Configure before enquiring
Open the interactive builder with Copper Plumbing Tubes preselected. Use it to organise the type, nominal size, standard, grade, temper, length, quantity and destination for technical review.
State Type K, L, M or DWV exactly as shown in the project requirement.
Add ASTM B88/B88M or EN 1057, nominal size, grade, temper and length.
Add MTC, test, marking, approval, inspection, packing and destination requirements.
Wall comparison
For a given nominal size, Types K, L and M have the same outside diameter but different wall thicknesses. Values below are published references; use the governing standard for purchase and design.
Building-services applications
Domestic or commercial water distribution where the selected tube type and material comply with the project requirements.
Type K is commonly specified, but burial conditions, corrosion protection and local code must be reviewed.
Copper plumbing tube for applicable closed-loop heating service based on temperature, pressure and system chemistry.
Selected tube types may be used where the fire code, listing and system design explicitly permit copper tube.
DWV tube for non-pressure drainage applications under the relevant plumbing code.
Cut lengths and defined tube conditions for modular plumbing assemblies and controlled installation work.
Evaluate water chemistry, velocity, temperature, pressure, disinfection practice, joining materials and stagnation risk. The material alone does not guarantee system performance.
Domestic and export enquiries
Indigo Metalloys manufactures at Timbhi Village, Umbergaon, District Valsad, Gujarat. State the project location and destination so the standard, marking, packing and commercial scope can be reviewed.
Contractor, distributor and project enquiries are welcome from:
Project and distribution requirements may be submitted from:
Locations indicate markets from which enquiries may be evaluated. They do not represent local offices, stock points, approvals or guaranteed delivery commitments.
Compliance and order definition
Specify the exact tube standard, type, grade, dimensions, temper, tests, marking and any potable-water approval required by the destination project.
View quality and testing capabilities →Standard and typeASTM B88/B88M or EN 1057; K, L, M or DWV
DimensionsNominal size, OD, wall and length
Material conditionAlloy, temper, finish, ends and marking
ComplianceMTC, tests, approvals and TPI
Commercial scopeQuantity, packing, project city, country and port
Before requesting a quotation
For the same nominal size, all three have the same outside diameter. Type K has the heaviest wall, Type L a medium wall and Type M a lighter wall. The engineer and applicable code determine which type is permitted.
ASTM B88/B88M covers seamless copper water tube. ASTM B42 covers seamless copper pipe for general applications and uses a different dimensional basis. Purchase to the standard stated by the project.
Do not substitute by appearance or outside diameter. ACR tube follows refrigerant-service requirements and actual-OD sizing, while plumbing tube follows the applicable water-tube standard and nominal type system.
No. Type M is not accepted for every service or jurisdiction. Confirm the adopted plumbing code, pressure, temperature and installation conditions before specifying it.
No. Material grade and product standard do not automatically prove every regional drinking-water approval. State NSF/ANSI 61 or other required approval in the RFQ and confirm the available evidence.
Yes. Open the 3D product builder with Copper Plumbing Tubes selected, prepare the requirement and send it for review.
Related copper products
Copper plumbing tube enquiry
Send the standard, type, grade, nominal size, wall, temper, length, quantity, approval, inspection and destination.
The available manufacturing, certification and delivery scope is confirmed before order acceptance.