ACR Copper Tubes Manufacturer in India

Specify clean, dry and sealed refrigeration copper tubing for split AC, VRF/VRV, chillers, cold rooms and engineered HVACR systems.

ACR copper tubes for air conditioning and refrigeration systems
Product familyAir Conditioning & Refrigeration Copper Tube
Primary standardsASTM B280 · EN 12735-1OD range6.35–104.8 mmTempersO60 · H58DocumentationEN 10204 3.1

Refrigeration-grade copper tubing

Protect the refrigerant circuit with the correct tube specification.

ACR means air conditioning and refrigeration. ACR copper tube is ordered by actual outside diameter and supplied for sealed refrigerant systems. The published group range covers C12200 DHP and C10200 oxygen-free copper in soft coils, level-wound coils and hard-drawn straight lengths.

The internal condition matters as much as the dimensions. Refrigeration copper tubing should be clean, dry and sealed to control moisture and contamination before installation. State the standard, alloy, OD, wall, temper, supply form, length, refrigerant, quantity and required documents in the RFQ.

A more reliable HVACR purchase

Reduce specification gaps before material reaches the site.

01

Choose ACR instead of plumbing tube

ASTM B280 and EN 12735-1 identify refrigeration service, actual-OD sizing and the required internal condition.

02

Select the correct supply form

Choose O60 soft pancake coil, level-wound coil for OEM processing or H58 hard-drawn straight tube.

03

Confirm cleanliness and sealing

Specify clean, dry, oil-free interiors and capped or sealed ends before quotation and dispatch.

04

Configure the product visually

Use the 3D product builder to organise the tube form and purchasing information before technical review.

Final refrigerant suitability and working conditions remain the responsibility of the system designer and governing project specification.

Technical specification

Published ACR copper tube supply range

Values are based on the group’s published ACR range. Final tolerances, wall selection, pressure suitability and availability are confirmed against the governing standard and RFQ.

01GradesC12200 DHP · C10200 OF
02Primary standardsASTM B280 · EN 12735-1
03Outside diameter6.35–104.8 mm
¼–4⅛ inch
04Wall thickness0.6–3.5 mm
05Soft conditionO60 annealed coil
06Hard conditionH58 drawn straight
07Supply formsPancake coil · LWC · straight
08LengthsStraight up to 6 m
Coils 15, 30 or 50 m
09Internal conditionClean, dry, degreased and sealed

Other referenced standards include JIS H3300 C1220T, AS 1571 and BS 2871 C106. Confirm the required edition and all project-specific cleanliness criteria.

Material and service identity

C12200 ACR copper reference composition

Chemistry identifies the copper grade; ASTM B280 or EN 12735-1 defines the finished refrigeration tube requirements.

ASTM B280Type ACR field-service tubeEN 12735-1Refrigeration and air-conditioning tubeUNS C12200Phosphorus-deoxidised copperO60Soft annealed coilH58Hard-drawn straightEN 102043.1 material certificate
Element or propertyPublished referencePurchasing significance
Copper plus silver99.9% minimumBase purity for C12200 DHP copper
Phosphorus0.015–0.040%Deoxidised copper chemistry suited to brazed tube applications
Oxygen0.001% maximumControlled oxygen content for DHP grade
InteriorClean, dry and oil-freeHelps control contamination inside a sealed refrigerant circuit
EndsCapped or sealedMaintains internal condition during handling and transport

Configure before enquiring

Build the ACR tube requirement in 3D.

Open the interactive builder with ACR Copper Tubes preselected. Use it to visualise the product and organise the grade, dimensions, temper, form, length, quantity and destination required for technical review.

01

Select supply form

Choose soft pancake coil, level-wound coil or hard-drawn straight tube.

02

Define tube details

State standard, grade, actual OD, wall, temper, length and refrigerant.

03

Confirm project scope

Add quantity, testing, MTC, TPI, packing and delivery destination.

Frequently ordered dimensions

ACR copper tube OD and wall reference

These published combinations are purchasing references. The system designer must confirm the wall and pressure rating for the refrigerant, temperatures, joining method and design code.

Actual outside diameterReference wallTypical purchasing form
¼ inch · 6.35 mm0.71 mmO60 soft coil
⅜ inch · 9.52 mm0.71 mmO60 soft coil / straight
½ inch · 12.70 mm0.71 mmCoil or straight
⅝ inch · 15.88 mm0.89 mmCoil or straight
¾ inch · 19.05 mm0.89 mmCoil or straight
⅞ inch · 22.22 mm0.89 mmCoil or hard-drawn straight
1⅛ inch · 28.58 mm1.02 mmCoil or hard-drawn straight
1⅜ inch · 34.92 mm1.07 mmHard-drawn straight / project coil
1⅝ inch · 41.28 mm1.07 mmHard-drawn straight
2⅛ inch · 53.98 mm1.07 mmHard-drawn straight
Actual OD sizingO60 soft coilH58 hard drawn15 / 30 / 50 m coilUp to 6 m straightSealed ends
B280ASTM field-service standard for ACR copper tube
−40°CPublished internal dew-point reference
3Supply forms: pancake coil, LWC and straight tube
3.1EN 10204 material test certificate

HVACR system applications

Refrigeration copper tubing selected around the system design

01

Split and ducted AC

Suction and liquid refrigerant lines sized by the system designer and equipment requirements.

02

VRF and VRV systems

Branch and distribution piping where cleanliness, tube sizing and approved brazing practice are critical.

03

Commercial refrigeration

Refrigeration copper pipe for cold rooms, display equipment and packaged refrigeration systems.

04

Chiller installations

Interconnecting ACR tubing selected for refrigerant, pressure, temperature and project code.

05

Industrial process cooling

HVACR copper tube for engineered cooling circuits and temperature-control equipment.

06

OEM production

Level-wound coils for controlled feeding, cutting and forming on manufacturing lines.

Selection note

Do not select ACR wall thickness from equipment tonnage alone. Confirm refrigerant, design pressure, operating temperatures, OD, joint type and applicable code.

Domestic and export enquiries

ACR copper tube enquiries from India and international HVACR markets.

Indigo Metalloys manufactures at Timbhi Village, Umbergaon, District Valsad, Gujarat. Include the project city or destination country and port so packaging, certificates and commercial terms can be reviewed.

IN
India-wide enquiries

Major HVACR and industrial markets

Contractor, OEM and distributor enquiries are welcome from:

  • Mumbai
  • Thane
  • Pune
  • Ahmedabad
  • Surat
  • Vadodara
  • Delhi NCR
  • Chennai
  • Bengaluru
  • Hyderabad
  • Kolkata
  • Kochi
  • Visakhapatnam
  • Coimbatore
  • Jaipur
  • Lucknow
EX
Export enquiries

Countries and international markets

Project and distribution requirements may be submitted from:

  • United Arab Emirates
  • Saudi Arabia
  • Qatar
  • Oman
  • Kuwait
  • Bahrain
  • Kenya
  • South Africa
  • Egypt
  • Singapore
  • Malaysia
  • United Kingdom
  • Germany
  • United States
  • Canada
  • Australia
  • Greece
  • Turkey

Locations identify markets from which enquiries may be evaluated. They do not represent local offices, stock points or guaranteed delivery commitments.

ACR tube forms and system language

Match the copper tube form to the HVACR purchasing requirement.

01

Pancake and soft copper coils

Bright-annealed pancake copper coil and flexible copper tube coil are intended for routed refrigerant lines. State actual OD, wall thickness, coil length, O60 temper and sealed-end requirements.

02

VRF and VRV copper tubing

For VRF or VRV piping, provide the equipment schedule, refrigerant, line duty and design pressure so the specified tube size and wall can be reviewed.

03

Hard-drawn straight tube

H58 straight copper tube supports plant-room, riser and fabricated assemblies where alignment and dimensional control matter.

04

Chiller and refrigeration systems

Chiller, cold-room and refrigeration copper tube enquiries should identify the applicable standard, cleanliness, joining process, operating conditions and inspection scope.

Choose the correct page

Use ASTM B280 Copper Tubes for exact-standard procurement and Level Wound Copper Coils for OEM processing coils.

Cleanliness, traceability and inspection

Define the refrigerant-service requirements before dispatch.

Ask for the applicable MTC, cleanliness condition, end sealing, inspection scope, marking and export documents in the original enquiry.

View quality and testing capabilities →
  1. 01

    StandardASTM B280, EN 12735-1 or project specification

  2. 02

    DimensionsActual OD, wall, length and tolerance

  3. 03

    Supply conditionO60 coil, H58 straight or LWC

  4. 04

    Internal conditionClean, dry, degreased and sealed

  5. 05

    Commercial scopeQuantity, documents, packing and destination

Before requesting a quotation

Frequently asked questions about ACR copper tubes

What does ACR mean in copper tubing?+

ACR means air conditioning and refrigeration. It identifies copper tube prepared for sealed refrigerant service rather than ordinary water plumbing.

Is ACR tube measured by ID or OD?+

ACR copper tubing is ordered by actual outside diameter. The internal diameter changes with wall thickness and should not be used as the primary size description.

What is the difference between ACR tube and Type L plumbing tube?+

ASTM B280 ACR tube is actual-OD sized, internally clean and sealed for refrigerant service. Type L under ASTM B88 is nominally sized water tube. Use the product required by the system specification.

Which supply forms are available?+

The published range includes O60 soft pancake coils, level-wound coils for OEM use and H58 hard-drawn straight tubes.

Can ACR tubing be used with R410A or R32?+

The published range identifies these refrigerants among common applications. The engineer must confirm OD, wall thickness, working pressure, temperatures, joints and design code for the specific system.

Can I configure ACR Copper Tubes in the 3D builder?+

Yes. Open the 3D product builder with ACR Copper Tubes selected, prepare the requirement and send it for technical review.

ACR copper tube enquiry

Get an ACR quotation matched to the refrigerant system.

Send the standard, grade, actual OD, wall, temper, form, length, refrigerant, quantity, inspection and destination.

The available manufacturing, cleanliness, documentation and delivery scope is confirmed before order acceptance.

Send ACR tube RFQ →